drm/nouveau: Don't disable polling in fallback mode
When a fan is controlled via linear fallback without cstate, we shouldn't stop polling. Otherwise it won't be adjusted again and keeps running at an initial crazy pace. Fixes: 800efb4c2857 ("drm/nouveau/drm/therm/fan: add a fallback if no fan control is specified in the vbios") Bugzilla: https://bugzilla.suse.com/show_bug.cgi?id=1103356 Bugzilla: https://bugs.freedesktop.org/show_bug.cgi?id=107447 Reported-by: Thomas Blume <thomas.blume@suse.com> Signed-off-by: Takashi Iwai <tiwai@suse.de> Reviewed-by: Martin Peres <martin.peres@free.fr> Signed-off-by: Ben Skeggs <bskeggs@redhat.com>
This commit is contained in:
parent
15f77c4ade
commit
118780066e
@ -132,11 +132,12 @@ nvkm_therm_update(struct nvkm_therm *therm, int mode)
|
||||
duty = nvkm_therm_update_linear(therm);
|
||||
break;
|
||||
case NVBIOS_THERM_FAN_OTHER:
|
||||
if (therm->cstate)
|
||||
if (therm->cstate) {
|
||||
duty = therm->cstate;
|
||||
else
|
||||
poll = false;
|
||||
} else {
|
||||
duty = nvkm_therm_update_linear_fallback(therm);
|
||||
poll = false;
|
||||
}
|
||||
break;
|
||||
}
|
||||
immd = false;
|
||||
|