iio: adc: ad-sigma-delta: Document ABI for sigma delta adc
Add common calibration nodes for sigma delta adc. Signed-off-by: Guillaume Ranquet <granquet@baylibre.com> Link: https://patch.msgid.link/20241202-ad411x_calibration-v3-2-beb6aeec39e2@baylibre.com Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
This commit is contained in:
parent
031bdc8aee
commit
4d112ebd02
23
Documentation/ABI/testing/sysfs-bus-iio-adc-ad-sigma-delta
Normal file
23
Documentation/ABI/testing/sysfs-bus-iio-adc-ad-sigma-delta
Normal file
@ -0,0 +1,23 @@
|
|||||||
|
What: /sys/bus/iio/devices/iio:deviceX/in_voltageY_sys_calibration
|
||||||
|
KernelVersion: 5.5
|
||||||
|
Contact: linux-iio@vger.kernel.org
|
||||||
|
Description:
|
||||||
|
This attribute, if available, initiates the system calibration procedure. This is done on a
|
||||||
|
single channel at a time. Write '1' to start the calibration.
|
||||||
|
|
||||||
|
What: /sys/bus/iio/devices/iio:deviceX/in_voltageY_sys_calibration_mode_available
|
||||||
|
KernelVersion: 5.5
|
||||||
|
Contact: linux-iio@vger.kernel.org
|
||||||
|
Description:
|
||||||
|
This attribute, if available, returns a list with the possible calibration modes.
|
||||||
|
There are two available options:
|
||||||
|
"zero_scale" - calibrate to zero scale
|
||||||
|
"full_scale" - calibrate to full scale
|
||||||
|
|
||||||
|
What: /sys/bus/iio/devices/iio:deviceX/in_voltageY_sys_calibration_mode
|
||||||
|
KernelVersion: 5.5
|
||||||
|
Contact: linux-iio@vger.kernel.org
|
||||||
|
Description:
|
||||||
|
This attribute, if available, sets up the calibration mode used in the system calibration
|
||||||
|
procedure. Reading returns the current calibration mode.
|
||||||
|
Writing sets the system calibration mode.
|
@ -19,33 +19,9 @@ Description:
|
|||||||
the bridge can be disconnected (when it is not being used
|
the bridge can be disconnected (when it is not being used
|
||||||
using the bridge_switch_en attribute.
|
using the bridge_switch_en attribute.
|
||||||
|
|
||||||
What: /sys/bus/iio/devices/iio:deviceX/in_voltagex_sys_calibration
|
|
||||||
KernelVersion:
|
|
||||||
Contact: linux-iio@vger.kernel.org
|
|
||||||
Description:
|
|
||||||
Initiates the system calibration procedure. This is done on a
|
|
||||||
single channel at a time. Write '1' to start the calibration.
|
|
||||||
|
|
||||||
What: /sys/bus/iio/devices/iio:deviceX/in_voltage2-voltage2_shorted_raw
|
What: /sys/bus/iio/devices/iio:deviceX/in_voltage2-voltage2_shorted_raw
|
||||||
KernelVersion:
|
KernelVersion:
|
||||||
Contact: linux-iio@vger.kernel.org
|
Contact: linux-iio@vger.kernel.org
|
||||||
Description:
|
Description:
|
||||||
Measure voltage from AIN2 pin connected to AIN(+)
|
Measure voltage from AIN2 pin connected to AIN(+)
|
||||||
and AIN(-) shorted.
|
and AIN(-) shorted.
|
||||||
|
|
||||||
What: /sys/bus/iio/devices/iio:deviceX/in_voltagex_sys_calibration_mode_available
|
|
||||||
KernelVersion:
|
|
||||||
Contact: linux-iio@vger.kernel.org
|
|
||||||
Description:
|
|
||||||
Reading returns a list with the possible calibration modes.
|
|
||||||
There are two available options:
|
|
||||||
"zero_scale" - calibrate to zero scale
|
|
||||||
"full_scale" - calibrate to full scale
|
|
||||||
|
|
||||||
What: /sys/bus/iio/devices/iio:deviceX/in_voltagex_sys_calibration_mode
|
|
||||||
KernelVersion:
|
|
||||||
Contact: linux-iio@vger.kernel.org
|
|
||||||
Description:
|
|
||||||
Sets up the calibration mode used in the system calibration
|
|
||||||
procedure. Reading returns the current calibration mode.
|
|
||||||
Writing sets the system calibration mode.
|
|
||||||
|