mirror of
https://git.kernel.org/pub/scm/linux/kernel/git/next/linux-next.git
synced 2024-12-29 09:12:07 +00:00
iio: adc: ad-sigma-delta: Document ABI for sigma delta adc
Add common calibration nodes for sigma delta adc. Signed-off-by: Guillaume Ranquet <granquet@baylibre.com> Link: https://patch.msgid.link/20241202-ad411x_calibration-v3-2-beb6aeec39e2@baylibre.com Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
This commit is contained in:
parent
031bdc8aee
commit
4d112ebd02
23
Documentation/ABI/testing/sysfs-bus-iio-adc-ad-sigma-delta
Normal file
23
Documentation/ABI/testing/sysfs-bus-iio-adc-ad-sigma-delta
Normal file
@ -0,0 +1,23 @@
|
||||
What: /sys/bus/iio/devices/iio:deviceX/in_voltageY_sys_calibration
|
||||
KernelVersion: 5.5
|
||||
Contact: linux-iio@vger.kernel.org
|
||||
Description:
|
||||
This attribute, if available, initiates the system calibration procedure. This is done on a
|
||||
single channel at a time. Write '1' to start the calibration.
|
||||
|
||||
What: /sys/bus/iio/devices/iio:deviceX/in_voltageY_sys_calibration_mode_available
|
||||
KernelVersion: 5.5
|
||||
Contact: linux-iio@vger.kernel.org
|
||||
Description:
|
||||
This attribute, if available, returns a list with the possible calibration modes.
|
||||
There are two available options:
|
||||
"zero_scale" - calibrate to zero scale
|
||||
"full_scale" - calibrate to full scale
|
||||
|
||||
What: /sys/bus/iio/devices/iio:deviceX/in_voltageY_sys_calibration_mode
|
||||
KernelVersion: 5.5
|
||||
Contact: linux-iio@vger.kernel.org
|
||||
Description:
|
||||
This attribute, if available, sets up the calibration mode used in the system calibration
|
||||
procedure. Reading returns the current calibration mode.
|
||||
Writing sets the system calibration mode.
|
@ -19,33 +19,9 @@ Description:
|
||||
the bridge can be disconnected (when it is not being used
|
||||
using the bridge_switch_en attribute.
|
||||
|
||||
What: /sys/bus/iio/devices/iio:deviceX/in_voltagex_sys_calibration
|
||||
KernelVersion:
|
||||
Contact: linux-iio@vger.kernel.org
|
||||
Description:
|
||||
Initiates the system calibration procedure. This is done on a
|
||||
single channel at a time. Write '1' to start the calibration.
|
||||
|
||||
What: /sys/bus/iio/devices/iio:deviceX/in_voltage2-voltage2_shorted_raw
|
||||
KernelVersion:
|
||||
Contact: linux-iio@vger.kernel.org
|
||||
Description:
|
||||
Measure voltage from AIN2 pin connected to AIN(+)
|
||||
and AIN(-) shorted.
|
||||
|
||||
What: /sys/bus/iio/devices/iio:deviceX/in_voltagex_sys_calibration_mode_available
|
||||
KernelVersion:
|
||||
Contact: linux-iio@vger.kernel.org
|
||||
Description:
|
||||
Reading returns a list with the possible calibration modes.
|
||||
There are two available options:
|
||||
"zero_scale" - calibrate to zero scale
|
||||
"full_scale" - calibrate to full scale
|
||||
|
||||
What: /sys/bus/iio/devices/iio:deviceX/in_voltagex_sys_calibration_mode
|
||||
KernelVersion:
|
||||
Contact: linux-iio@vger.kernel.org
|
||||
Description:
|
||||
Sets up the calibration mode used in the system calibration
|
||||
procedure. Reading returns the current calibration mode.
|
||||
Writing sets the system calibration mode.
|
||||
|