Compared with the previous Amlogic-GXBB, the watchdog of Amlogic-T7
has a different reset enable bit.
Signed-off-by: Huqiang Qin <huqiang.qin@amlogic.com>
Reviewed-by: Dmitry Rokosov <ddrokosov@sberdevices.ru>
Reviewed-by: Guenter Roeck <linux@roeck-us.net>
Link: https://lore.kernel.org/r/20230802033222.4024946-4-huqiang.qin@amlogic.com
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Signed-off-by: Wim Van Sebroeck <wim@linux-watchdog.org>
The devm_clk_get_enabled() helper:
- calls devm_clk_get()
- calls clk_prepare_enable() and registers what is needed in order to
call clk_disable_unprepare() when needed, as a managed resource.
This simplifies the code and avoids the need of a dedicated function used
with devm_add_action_or_reset().
Signed-off-by: Christophe JAILLET <christophe.jaillet@wanadoo.fr>
Reviewed-by: Guenter Roeck <linux@roeck-us.net>
Reviewed-by: Martin Blumenstingl <martin.blumenstingl@googlemail.com>
Link: https://lore.kernel.org/r/6c5948373d309408095c1a098b7b4c491c5265f7.1672490071.git.christophe.jaillet@wanadoo.fr
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Signed-off-by: Wim Van Sebroeck <wim@linux-watchdog.org>
If the watchdog is already running (e.g.: started by bootloader) then
the kernel driver should keep the watchdog active but the amlogic driver
turns it off.
Let the driver fix the clock rate if already active because we do not
know the previous timebase value. To avoid unintentional resetting we
temporarily set it to its maximum value.
Then keep the enable bit if is was previously active.
Signed-off-by: Philippe Boos <pboos@baylibre.com>
Reviewed-by: Jerome Brunet <jbrunet@baylibre.com>
Reviewed-by: Guenter Roeck <linux@roeck-us.net>
Link: https://lore.kernel.org/r/20220801092150.4449-1-pboos@baylibre.com
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Signed-off-by: Wim Van Sebroeck <wim@linux-watchdog.org>
Remove watchdog_stop_on_reboot()
The Meson platform still has some hardware drivers problems for some
configurations which can freeze devices on shutdown/reboot.
Remove watchdog_stop_on_reboot() to catch this situation and ensure that
the reboot happens anyway. Users who still want to stop the watchdog on
reboot can still do so using the watchdog.stop_on_reboot=1 module
parameter.
https://lore.kernel.org/linux-watchdog/20210729072308.1908904-1-art@khadas.com/T/#t
Signed-off-by: Artem Lapkin <art@khadas.com>
Reviewed-by: Guenter Roeck <linux@roeck-us.net>
Link: https://lore.kernel.org/r/20211110022518.1676834-1-art@khadas.com
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Signed-off-by: Wim Van Sebroeck <wim@linux-watchdog.org>
The left time value is wrong when we get it by sysfs. The left time value
should be equal to preset timeout value minus elapsed time value. According
to the Meson-GXB/GXL datasheets which can be found at [0], the timeout value
is saved to BIT[0-15] of the WATCHDOG_TCNT, and elapsed time value is saved
to BIT[16-31] of the WATCHDOG_TCNT.
[0]: http://linux-meson.com
Fixes: 683fa50f0e ("watchdog: Add Meson GXBB Watchdog Driver")
Signed-off-by: Xingyu Chen <xingyu.chen@amlogic.com>
Acked-by: Neil Armstrong <narmstrong@baylibre.com>
Reviewed-by: Kevin Hilman <khilman@baylibre.com>
Reviewed-by: Guenter Roeck <linux@roeck-us.net>
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Signed-off-by: Wim Van Sebroeck <wim@linux-watchdog.org>
Use device managed functions to simplify error handling, reduce
source code size, improve readability, and reduce the likelyhood of bugs.
Other improvements as listed below.
The conversion was done automatically with coccinelle using the
following semantic patches. The semantic patches and the scripts
used to generate this commit log are available at
https://github.com/groeck/coccinelle-patches
- Drop assignments to otherwise unused variables
- Drop unnecessary braces around conditional return statements
- Drop empty remove function
- Use devm_add_action_or_reset() for calls to clk_disable_unprepare
- Introduce local variable 'struct device *dev' and use it instead of
dereferencing it repeatedly
- Use devm_watchdog_register_driver() to register watchdog device
- Replace shutdown function with call to watchdog_stop_on_reboot()
Cc: Kevin Hilman <khilman@baylibre.com>
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Signed-off-by: Wim Van Sebroeck <wim@linux-watchdog.org>
clk_prepare_enable() can fail here and we must check its return value.
Signed-off-by: Arvind Yadav <arvind.yadav.cs@gmail.com>
Reviewed-by: Guenter Roeck <linux@roeck-us.net>
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Signed-off-by: Wim Van Sebroeck <wim@iguana.be>
The Amlogic Meson is a DT-only platform, which means the devices are
registered via OF and not using the legacy platform devices support.
So there's no need to have a MODULE_ALIAS("platform:meson-gxbb-wdt")
since the reported uevent MODALIAS to user-space will be the OF one.
Signed-off-by: Javier Martinez Canillas <javier@osg.samsung.com>
Acked-by: Kevin Hilman <khilman@baylibre.com>
Reviewed-by: Guenter Roeck <linux@roeck-us.net>
Signed-off-by: Guenter Roeck <linux@roeck-us.net>