The power allocator governor is a thermal governor that controls system
and device power allocation to control temperature. Conceptually, the
implementation divides the sustainable power of a thermal zone among
all the heat sources in that zone.
This governor relies on "power actors", entities that represent heat
sources. They can report current and maximum power consumption and
can set a given maximum power consumption, usually via a cooling
device.
The governor uses a Proportional Integral Derivative (PID) controller
driven by the temperature of the thermal zone. The output of the
controller is a power budget that is then allocated to each power
actor that can have bearing on the temperature we are trying to
control. It decides how much power to give each cooling device based
on the performance they are requesting. The PID controller ensures
that the total power budget does not exceed the control temperature.
Cc: Zhang Rui <rui.zhang@intel.com>
Cc: Eduardo Valentin <edubezval@gmail.com>
Signed-off-by: Punit Agrawal <punit.agrawal@arm.com>
Signed-off-by: Javi Merino <javi.merino@arm.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
Add a basic power model to the cpu cooling device to implement the
power cooling device API. The power model uses the current frequency,
current load and OPPs for the power calculations. The cpus must have
registered their OPPs using the OPP library.
Cc: Zhang Rui <rui.zhang@intel.com>
Cc: Eduardo Valentin <edubezval@gmail.com>
Signed-off-by: Kapileshwar Singh <kapileshwar.singh@arm.com>
Signed-off-by: Punit Agrawal <punit.agrawal@arm.com>
Signed-off-by: Javi Merino <javi.merino@arm.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
Add three optional callbacks to the cooling device interface to allow
them to express power. In addition to the callbacks, add helpers to
identify cooling devices that implement the power cooling device API.
Cc: Zhang Rui <rui.zhang@intel.com>
Cc: Eduardo Valentin <edubezval@gmail.com>
Signed-off-by: Javi Merino <javi.merino@arm.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
A governor may need to store its current state between calls to
throttle(). That state depends on the thermal zone, so store it as
private data in struct thermal_zone_device.
The governors may have two new ops: bind_to_tz() and unbind_from_tz().
When provided, these functions let governors do some initialization
and teardown when they are bound/unbound to a tz and possibly store that
information in the governor_data field of the struct
thermal_zone_device.
Cc: Zhang Rui <rui.zhang@intel.com>
Cc: Eduardo Valentin <edubezval@gmail.com>
Signed-off-by: Javi Merino <javi.merino@arm.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
Add support for the temperature alarm peripheral found inside
Qualcomm plug-and-play (QPNP) PMIC chips. The temperature alarm
peripheral outputs a pulse on an interrupt line whenever the
thermal over temperature stage value changes.
Register a thermal sensor. The temperature reported by this thermal
sensor device should reflect the actual PMIC die temperature if an
ADC is present on the given PMIC. If no ADC is present, then the
reported temperature should be estimated from the over temperature
stage value.
Cc: David Collins <collinsd@codeaurora.org>
Signed-off-by: Ivan T. Ivanov <iivanov@mm-sol.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
The fair share governor has the concept of weights, which is the
influence of each cooling device in a thermal zone. The current
implementation forces the weights of all cooling devices in a thermal
zone to add up to a 100. This complicates setups, as you need to know
in advance how many cooling devices you are going to have. If you bind a
new cooling device, you have to modify all the other cooling devices
weights, which is error prone. Furthermore, you can't specify a
"default" weight for platforms since that default value depends on the
number of cooling devices in the platform.
This patch generalizes the concept of weight by allowing any number to
be a "weight". Weights are now relative to each other. Platforms that
don't specify weights get the same default value for all their cooling
devices, so all their cdevs are considered to be equally influential.
It's important to note that previous users of the weights don't need to
alter the code: percentages continue to work as they used to. This
patch just removes the constraint of all the weights in a thermal zone
having to add up to a 100. If they do, you get the same behavior as
before. If they don't, fair share now works for that platform.
Cc: Zhang Rui <rui.zhang@intel.com>
Cc: Eduardo Valentin <edubezval@gmail.com>
Cc: Durgadoss R <durgadoss.r@intel.com>
Acked-by: Durgadoss R <durgadoss.r@intel.com>
Signed-off-by: Javi Merino <javi.merino@arm.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
It's useful to have access to the weights for the cooling devices for
thermal zones and change them if needed. Export them to sysfs.
Cc: Zhang Rui <rui.zhang@intel.com>
Cc: Eduardo Valentin <edubezval@gmail.com>
Signed-off-by: Javi Merino <javi.merino@arm.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
The fair share governor is not usable with thermal zones that use the
bind op and don't populate thermal_zone_parameters, the majority of
them. Now that the weight is in the thermal instance, we can use that
in the fair share governor to allow every thermal zone to trivially use
this governor. Furthermore, this simplifies the code.
Cc: Zhang Rui <rui.zhang@intel.com>
Cc: Eduardo Valentin <edubezval@gmail.com>
Cc: Durgadoss R <durgadoss.r@intel.com>
Reviewed-by: Durgadoss R <durgadoss.r@intel.com>
Signed-off-by: Javi Merino <javi.merino@arm.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
Currently you can specify the weight of the cooling device in the device
tree but that information is not populated to the
thermal_bind_params where the fair share governor expects it to
be. The of thermal zone device doesn't have a thermal_bind_params
structure and arguably it's better to pass the weight inside the
thermal_instance as it is specific to the bind of a cooling device to a
thermal zone parameter.
Core thermal code is fixed to populate the weight in the instance from
the thermal_bind_params, so platform code that was passing the weight
inside the thermal_bind_params continue to work seamlessly.
While we are at it, create a default value for the weight parameter for
those thermal zones that currently don't define it and remove the
hardcoded default in of-thermal.
Cc: Zhang Rui <rui.zhang@intel.com>
Cc: "Rafael J. Wysocki" <rjw@rjwysocki.net>
Cc: Len Brown <lenb@kernel.org>
Cc: Peter Feuerer <peter@piie.net>
Cc: Darren Hart <dvhart@infradead.org>
Cc: Eduardo Valentin <edubezval@gmail.com>
Cc: Kukjin Kim <kgene@kernel.org>
Cc: Durgadoss R <durgadoss.r@intel.com>
Signed-off-by: Kapileshwar Singh <kapileshwar.singh@arm.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
Simple patch to make symbols static. Symbols that are not
shared with other parts of the kernel can be made static.
This change also removes several sparse complains.
Cc: Zhang Rui <rui.zhang@intel.com>
Cc: Lee Jones <lee.jones@linaro.org>
Cc: Pavel Machek <pavel@ucw.cz>
Cc: Ajit Pal Singh <ajitpal.singh@st.com>
Cc: linux-pm@vger.kernel.org
Cc: linux-kernel@vger.kernel.org
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
of_device_id is always used as const.
(See driver.of_match_table and open firmware functions)
Signed-off-by: Fabian Frederick <fabf@skynet.be>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
Some temperature sensors only get updated every few seconds and while
waiting for the first irq reporting a (new) temperature to happen there
get_temp operand will return -EAGAIN as it does not have any data to report
yet.
Not logging an error in this case avoids messages like these from showing
up in dmesg on affected systems:
[ 1.219353] thermal thermal_zone0: failed to read out thermal zone 0
[ 2.015433] thermal thermal_zone0: failed to read out thermal zone 0
[ 2.416737] thermal thermal_zone0: failed to read out thermal zone 0
Reviewed-by: Dmitry Torokhov <dmitry.torokhov@gmail.com>
Signed-off-by: Hans de Goede <hdegoede@redhat.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
Default attributes are created when the device is registered. Attributes
created after device registration can lead to race conditions, where user space
(e.g. udev) sees the device but not the attributes.
Signed-off-by: Matthias Kaehlcke <mka@chromium.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
When thermal zone device register fails or on module exit, the memory
for aux_trip is not freed. This change fixes this issue.
Signed-off-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
This patch fixes the wrong control of PD_DET_EN (power down detection mode)
for Exynos7 because exynos7_tmu_control() always enables the power down detection
mode regardless 'on' parameter.
Cc: Zhang Rui <rui.zhang@intel.com>
Cc: Eduardo Valentin <edubezval@gmail.com>
Signed-off-by: Chanwoo Choi <cw00.choi@samsung.com>
Tested-by: Abhilash Kesavan <a.kesavan@samsung.com>
Signed-off-by: Lukasz Majewski <l.majewski@samsung.com>
It is possible that _ART/_TRT tables are missing or have errors.
Ignore those failures, as INT3400 thermal zone is still required
for _OSC or mode switch.
Signed-off-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
Enable Intel Powerclamp driver on Atom* Processor C2000 Product
Family for Microservers (Avoton). Avoton - SoCs for micro-servers
has package C-states which can be used for idle injection.
Reported-by: Jose Navarro <jose.navarro@intel.com>
Suggested-by: Jacob Pan <jacob.jun.pan@linux.intel.com>
Tested-by: Jose Carlos Venegas Munoz <jos.c.venegas.munoz@intel.com>
Signed-off-by: Miguel Bernal Marin <miguel.bernal.marin@linux.intel.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
Swap interrupt disable and thermal zone unregistration in the error and
remove paths, to make them more symmetrical with the initialization
path.
Signed-off-by: Geert Uytterhoeven <geert+renesas@glider.be>
Acked-by: Kuninori Morimoto <kuninori.morimoto.gx@renesas.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
As soon as the interrupt has been enabled by devm_request_irq(), the
interrupt routine may be called, depending on the current status of the
hardware.
However, at that point rcar_thermal_common hasn't been initialized
complely yet. E.g. rcar_thermal_common.base is still NULL, causing a
NULL pointer dereference:
Unable to handle kernel NULL pointer dereference at virtual address 0000000c
pgd = c0004000
[0000000c] *pgd=00000000
Internal error: Oops: 5 [#1] SMP ARM
CPU: 0 PID: 1 Comm: swapper/0 Not tainted 3.19.0-rc7-ape6evm-04564-gb6e46cb7cbe82389 #30
Hardware name: Generic R8A73A4 (Flattened Device Tree)
task: ee8953c0 ti: ee896000 task.ti: ee896000
PC is at rcar_thermal_irq+0x1c/0xf0
LR is at _raw_spin_lock_irqsave+0x48/0x54
Postpone the call to devm_request_irq() until all initialization has
been done to fix this.
Signed-off-by: Geert Uytterhoeven <geert+renesas@glider.be>
Acked-by: Kuninori Morimoto <kuninori.morimoto.gx@renesas.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
The cpufreq_cooling_unregister() function tests whether its argument is NULL
and then returns immediately. Thus the test around the call is not needed.
This issue was detected by using the Coccinelle software.
Signed-off-by: Markus Elfring <elfring@users.sourceforge.net>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
Fix following build warning if CONFIG_PM_SLEEP is not set:
drivers/thermal/ti-soc-thermal/ti-bandgap.c:1478:12: warning: 'ti_bandgap_suspend' defined but not used [-Wunused-function]
static int ti_bandgap_suspend(struct device *dev)
^
drivers/thermal/ti-soc-thermal/ti-bandgap.c:1492:12: warning: 'ti_bandgap_resume' defined but not used [-Wunused-function]
static int ti_bandgap_resume(struct device *dev)
^
Acked-by: Nishanth Menon <nm@ti.com>
Signed-off-by: Grygorii Strashko <Grygorii.Strashko@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
The exynos_tmu_data() function should on entrance test not only for valid
data pointer, but also for data->tmu_read one.
It is important, since afterwards it is dereferenced to get temperature code.
Signed-off-by: Lukasz Majewski <l.majewski@samsung.com>
Tested-by: Abhilash Kesavan <a.kesavan@samsung.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
Pull more thermal managament updates from Zhang Rui:
"Specifics:
- Exynos thermal driver refactoring. Several cleanups, code
optimization, unused symbols removal, and unused feature removal in
Exynos thermal driver. Thanks Lukasz for this effort.
- Exynos thermal driver support to OF thermal. After the code
refactoring, the driver earned the support to OF thermal. Chip
thermal data were moved from driver code to DTS, reducing the code
footprint. Thanks Lukasz for this.
- After receiving the OF thermal support, the exynos thermal driver
now must allow modular build. Thanks Arnd for detecting, reporting
and fixing this.
- Exynos thermal driver support to Exynos 7 SoC. Thanks Abhilash for
this.
- Accurate temperature reporting on Rockchip thermal driver, thanks
to Caesar.
- Fix on how OF thermal enables its zones, thanks Lukasz for fixing.
- Fixes in OF thermal examples under Documentation/. Thanks Srinivas
for fixing"
* 'fixes' of git://git.kernel.org/pub/scm/linux/kernel/git/evalenti/linux-soc-thermal:
thermal: exynos: Add TMU support for Exynos7 SoC
dts: Documentation: Add documentation for Exynos7 SoC thermal bindings
cpufreq: exynos: allow modular build
thermal: Fix examples in DT documentation
thermal: exynos: Correct sanity check at exynos_report_trigger() function
thermal: Kconfig: Remove config for not used EXYNOS_THERMAL_CORE
thermal: exynos: Remove exynos_tmu_data.c file
thermal: rockchip: make temperature reporting much more accurate
thermal: exynos: Remove exynos_thermal_common.[c|h] files
thermal: samsung: core: Exynos TMU rework to use device tree for configuration
dts: Documentation: Update exynos-thermal.txt example for Exynos5440
dts: Documentation: Extending documentation entry for exynos-thermal
cpufreq: exynos: Use device tree to determine if cpufreq cooling should be registered
thermal: exynos: Modify exynos thermal code to use device tree for cpu cooling configuration
thermal: exynos: Provide thermal_exynos.h file to be included in device tree files
thermal: exynos: cosmetic: Correct comment format
thermal: of: Enable thermal_zoneX when sensor is correctly added
Pull thermal managament updates from Zhang Rui:
"Specifics:
- Abstract the code and introduce helper functions for all int340x
thermal drivers. From: Srinivas Pandruvada.
- Reorganize the ACPI LPAT table support code so that it can be
shared for both ACPI PMIC driver and int340x thermal driver.
- Add support for Braswell in intel_soc_dts thermal driver.
- a couple of small fixes/cleanups for step_wise governor and int340x
thermal driver"
* 'next' of git://git.kernel.org/pub/scm/linux/kernel/git/rzhang/linux:
Thermal/int340x_thermal: remove unused uuids.
thermal: step_wise: spelling fixes
thermal: int340x: fix sparse warning
Thermal/int340x: LPAT conversion for temperature
ACPI / PMIC: Use common LPAT table handling functions
ACPI / LPAT: Common table processing functions
thermal: Intel SoC DTS: Add Braswell support
Thermal/int340x/int3402: Provide notification support
Thermal/int340x/processor_thermal: Add thermal zone support
Thermal/int340x/int3403: Use int340x thermal API
Thermal/int340x/int3402: Use int340x thermal API
Thermal/int340x: Add common thermal zone handler
this patch fixes following sparse warning:
processor_thermal_device.c:188:6: warning: symbol 'proc_thermal_remove' was not declared. Should it be static?
Signed-off-by: Lad, Prabhakar <prabhakar.csengg@gmail.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
Add registers, bit fields and compatible strings for Exynos7 TMU
(Thermal Management Unit). Following are a few of the differences
in the Exynos7 TMU from earlier SoCs:
- 8 trigger levels
- Different bit offsets and more registers for the rising
and falling thresholds.
- New power down detection bit in the TMU_CONTROL register
which does not update the CURRENT_TEMP0 when tmu power down
is detected.
- Change in bit offset for the NEXT_DATA field of EMUL_CON
register. EMUL_CON register address has also changed.
- INTSTAT and INTCLEAR registers present in earlier SoCs
have been combined into one INTPEND register. The register
address for INTCLEAR and INTPEND is also different.
- Since there are 8 rising/falling interrupts as against
at most 4 in earlier SoCs the INTEN bit offsets are different.
- Multiple probe support which is handled by a TMU_CONTROL1
register (No support for this in the current patch).
This patch adds special clock support required only for Exynos7. It
also updates the "code_to_temp" prototype as Exynos7 has 9 bit
code-temp mapping.
Acked-by: Lukasz Majewski <l.majewski@samsung.com>
Tested-by: Lukasz Majewski <l.majewski@samsung.com>
Signed-off-by: Abhilash Kesavan <a.kesavan@samsung.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
When LPAT table is present, we need to convert raw temperature to
real temp using LPAT.
Signed-off-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
Added Intel Braswell CPU id for SOC DTS. Since this doesn't support
APIC IRQ, the driver is modified to have capability to not register
any modifiable trips.
Signed-off-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
Up till now, by mistake, wrong variable was tested against being NULL.
Since exynos_report_trigger() is always called with valid p pointer,
it is only necessary to check if a valid thermal zone device is passed.
Reported-by: Dan Carpenter <dan.carpenter@oracle.com>
Signed-off-by: Lukasz Majewski <l.majewski@samsung.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
Conflicts:
arch/arm/boot/dts/imx6sx-sdb.dts
net/sched/cls_bpf.c
Two simple sets of overlapping changes.
Signed-off-by: David S. Miller <davem@davemloft.net>
After removing exynos_thermal_common.[c|h] files the CONFIG_EXYNOS_THERMA_CORE
is not needed anymore.
This patch removes this entry from Kconfig.
Reported-by: Paul Bolle <pebolle@tiscali.nl>
Signed-off-by: Lukasz Majewski <l.majewski@samsung.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
Data already present in the exynos_tmu_data.c file has been moved to the
appropriate device tree files.
Signed-off-by: Lukasz Majewski <l.majewski@samsung.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
In general, the kernel should report temperature readings exactly as
reported by the hardware. The cpu / gpu thermal driver works in 5 degree
increments,but we ought to do more accurate. The temperature will do
linear interpolation between the entries in the table.
Test= $md5sum /dev/zero &
$while true; do grep "" /sys/class/thermal/thermal_zone[1-2]/temp;
sleep .5; done
e.g. We can get the result as follows:
/sys/class/thermal/thermal_zone1/temp:39994
/sys/class/thermal/thermal_zone2/temp:39086
/sys/class/thermal/thermal_zone1/temp:39994
/sys/class/thermal/thermal_zone2/temp:39540
/sys/class/thermal/thermal_zone1/temp:39540
/sys/class/thermal/thermal_zone2/temp:39540
/sys/class/thermal/thermal_zone1/temp:39540
/sys/class/thermal/thermal_zone2/temp:39994
Reviewed-by: Dmitry Torokhov <dmitry.torokhov@gmail.com>
Reviewed-by: Daniel Kurtz <djkurtz@chromium.org>
Signed-off-by: Caesar Wang <wxt@rock-chips.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
After defining all necessary Exynos data in the device tree and heavy
reusage of the of-thermal.c those files can be removed.
Signed-off-by: Lukasz Majewski <l.majewski@samsung.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
This patch brings support for providing configuration via device tree.
Previously this data has been hardcoded in the exynos_tmu_data.c file.
Such approach was not scalable and very often required copying the whole
data.
Signed-off-by: Lukasz Majewski <l.majewski@samsung.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
Up till now exynos_tmu_data.c was used for storing CPU cooling configuration
data. Now the Exynos thermal core code uses device tree to get this data.
For this purpose generic thermal code for configuring CPU cooling was
used.
Signed-off-by: Lukasz Majewski <l.majewski@samsung.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
This patch is a preparatory patch to be able to read Exynos thermal
configuration from the device tree.
It turned out that DTC is not able to interpret enums properly and hence
it is necessary to #define those values explicitly.
For this reason the ./include/dt-bindings/thermal/thermal_exynos.h file
has been introduced.
Signed-off-by: Lukasz Majewski <l.majewski@samsung.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
Up till now the thermal_zone mode was by default "disabled". With this
patch the default behavior was changed to "enable".
One can read the mode at:
/sys/class/thermal/thermal_zone0/mode
Tested-by: Javi Merino <javi.merino@arm.com>
Reported-by: Abhilash Kesavan <a.kesavan@samsung.com>
Signed-off-by: Lukasz Majewski <l.majewski@samsung.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
Added thermal zones for processor thermal using APIs provided by
int340x thermal zone module.
Like other INT340x devices, processor thermal device can also contain
trip points and way to get temperature. On some platform there is
no ACPI _TMP method, in those platform using IA64 architecture MSRs to
get temperature.
Signed-off-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
Using APIs from int340x thermal zone module to add and remove thermal
zones.
Signed-off-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
Using APIs from int340x thermal zone module to add and remove thermal
zones.
Signed-off-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
Most of the processing for each int340x driver to add a thermal zone
is very similar and every driver has to duplicate code.
Created a common module, which exports API to add and remove zones.
In this way, we not only avoid duplicate code but also helps in
bug fixes and enhancements.
If for some driver default processing for thermal zone callback is
not enough they can overide individual callback.
The code for this driver is primarily copied from int3402_thermal.c.
Signed-off-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
Contrary to common expectations for an "int" return, these functions
return only a positive value -- if used correctly they cannot even
return 0 because the message header will necessarily be in the skb.
This makes the very common pattern of
if (genlmsg_end(...) < 0) { ... }
be a whole bunch of dead code. Many places also simply do
return nlmsg_end(...);
and the caller is expected to deal with it.
This also commonly (at least for me) causes errors, because it is very
common to write
if (my_function(...))
/* error condition */
and if my_function() does "return nlmsg_end()" this is of course wrong.
Additionally, there's not a single place in the kernel that actually
needs the message length returned, and if anyone needs it later then
it'll be very easy to just use skb->len there.
Remove this, and make the functions void. This removes a bunch of dead
code as described above. The patch adds lines because I did
- return nlmsg_end(...);
+ nlmsg_end(...);
+ return 0;
I could have preserved all the function's return values by returning
skb->len, but instead I've audited all the places calling the affected
functions and found that none cared. A few places actually compared
the return value with <= 0 in dump functionality, but that could just
be changed to < 0 with no change in behaviour, so I opted for the more
efficient version.
One instance of the error I've made numerous times now is also present
in net/phonet/pn_netlink.c in the route_dumpit() function - it didn't
check for <0 or <=0 and thus broke out of the loop every single time.
I've preserved this since it will (I think) have caused the messages to
userspace to be formatted differently with just a single message for
every SKB returned to userspace. It's possible that this isn't needed
for the tools that actually use this, but I don't even know what they
are so couldn't test that changing this behaviour would be acceptable.
Signed-off-by: Johannes Berg <johannes.berg@intel.com>
Signed-off-by: David S. Miller <davem@davemloft.net>