mirror of
https://git.kernel.org/pub/scm/linux/kernel/git/next/linux-next.git
synced 2024-12-28 16:52:18 +00:00
a5a98a786e
Add and use a special guard for cooling devices. This allows quite a few error code paths to be simplified among other things and brings in code size reduction for a good measure. No intentional functional impact. Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com> Link: https://patch.msgid.link/5837621.DvuYhMxLoT@rjwysocki.net Reviewed-by: Lukasz Luba <lukasz.luba@arm.com>
142 lines
4.1 KiB
C
142 lines
4.1 KiB
C
// SPDX-License-Identifier: GPL-2.0-only
|
|
/*
|
|
* step_wise.c - A step-by-step Thermal throttling governor
|
|
*
|
|
* Copyright (C) 2012 Intel Corp
|
|
* Copyright (C) 2012 Durgadoss R <durgadoss.r@intel.com>
|
|
*
|
|
* ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
*
|
|
* ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
*/
|
|
|
|
#include <linux/thermal.h>
|
|
#include <linux/minmax.h>
|
|
#include "thermal_trace.h"
|
|
|
|
#include "thermal_core.h"
|
|
|
|
/*
|
|
* If the temperature is higher than a trip point,
|
|
* a. if the trend is THERMAL_TREND_RAISING, use higher cooling
|
|
* state for this trip point
|
|
* b. if the trend is THERMAL_TREND_DROPPING, do nothing
|
|
* If the temperature is lower than a trip point,
|
|
* a. if the trend is THERMAL_TREND_RAISING, do nothing
|
|
* b. if the trend is THERMAL_TREND_DROPPING, use lower cooling
|
|
* state for this trip point, if the cooling state already
|
|
* equals lower limit, deactivate the thermal instance
|
|
*/
|
|
static unsigned long get_target_state(struct thermal_instance *instance,
|
|
enum thermal_trend trend, bool throttle)
|
|
{
|
|
struct thermal_cooling_device *cdev = instance->cdev;
|
|
unsigned long cur_state;
|
|
|
|
/*
|
|
* We keep this instance the way it is by default.
|
|
* Otherwise, we use the current state of the
|
|
* cdev in use to determine the next_target.
|
|
*/
|
|
cdev->ops->get_cur_state(cdev, &cur_state);
|
|
dev_dbg(&cdev->device, "cur_state=%ld\n", cur_state);
|
|
|
|
if (!instance->initialized) {
|
|
if (throttle)
|
|
return clamp(cur_state + 1, instance->lower, instance->upper);
|
|
|
|
return THERMAL_NO_TARGET;
|
|
}
|
|
|
|
if (throttle) {
|
|
if (trend == THERMAL_TREND_RAISING)
|
|
return clamp(cur_state + 1, instance->lower, instance->upper);
|
|
} else if (trend == THERMAL_TREND_DROPPING) {
|
|
if (cur_state <= instance->lower)
|
|
return THERMAL_NO_TARGET;
|
|
|
|
/*
|
|
* If 'throttle' is false, no mitigation is necessary, so
|
|
* request the lower state for this instance.
|
|
*/
|
|
return instance->lower;
|
|
}
|
|
|
|
return instance->target;
|
|
}
|
|
|
|
static void thermal_zone_trip_update(struct thermal_zone_device *tz,
|
|
const struct thermal_trip_desc *td,
|
|
int trip_threshold)
|
|
{
|
|
const struct thermal_trip *trip = &td->trip;
|
|
enum thermal_trend trend = get_tz_trend(tz, trip);
|
|
int trip_id = thermal_zone_trip_id(tz, trip);
|
|
struct thermal_instance *instance;
|
|
bool throttle = false;
|
|
|
|
if (tz->temperature >= trip_threshold) {
|
|
throttle = true;
|
|
trace_thermal_zone_trip(tz, trip_id, trip->type);
|
|
}
|
|
|
|
dev_dbg(&tz->device, "Trip%d[type=%d,temp=%d]:trend=%d,throttle=%d\n",
|
|
trip_id, trip->type, trip_threshold, trend, throttle);
|
|
|
|
list_for_each_entry(instance, &td->thermal_instances, trip_node) {
|
|
int old_target;
|
|
|
|
old_target = instance->target;
|
|
instance->target = get_target_state(instance, trend, throttle);
|
|
|
|
dev_dbg(&instance->cdev->device, "old_target=%d, target=%ld\n",
|
|
old_target, instance->target);
|
|
|
|
if (instance->initialized && old_target == instance->target)
|
|
continue;
|
|
|
|
instance->initialized = true;
|
|
|
|
scoped_guard(cooling_dev, instance->cdev) {
|
|
instance->cdev->updated = false; /* cdev needs update */
|
|
}
|
|
}
|
|
}
|
|
|
|
static void step_wise_manage(struct thermal_zone_device *tz)
|
|
{
|
|
const struct thermal_trip_desc *td;
|
|
struct thermal_instance *instance;
|
|
|
|
lockdep_assert_held(&tz->lock);
|
|
|
|
/*
|
|
* Throttling Logic: Use the trend of the thermal zone to throttle.
|
|
* If the thermal zone is 'heating up', throttle all of the cooling
|
|
* devices associated with each trip point by one step. If the zone
|
|
* is 'cooling down', it brings back the performance of the devices
|
|
* by one step.
|
|
*/
|
|
for_each_trip_desc(tz, td) {
|
|
const struct thermal_trip *trip = &td->trip;
|
|
|
|
if (trip->temperature == THERMAL_TEMP_INVALID ||
|
|
trip->type == THERMAL_TRIP_CRITICAL ||
|
|
trip->type == THERMAL_TRIP_HOT)
|
|
continue;
|
|
|
|
thermal_zone_trip_update(tz, td, td->threshold);
|
|
}
|
|
|
|
for_each_trip_desc(tz, td) {
|
|
list_for_each_entry(instance, &td->thermal_instances, trip_node)
|
|
thermal_cdev_update(instance->cdev);
|
|
}
|
|
}
|
|
|
|
static struct thermal_governor thermal_gov_step_wise = {
|
|
.name = "step_wise",
|
|
.manage = step_wise_manage,
|
|
};
|
|
THERMAL_GOVERNOR_DECLARE(thermal_gov_step_wise);
|