The NPCM750 Timer/Watchdog Controller has multiple interrupt lines, connected to multiple timers. The driver uses timer 0 for timer interrupts, so the interrupt line corresponding to timer 0 should be specified in DT. I removed the mention of "flags for falling edge", because the timer controller uses high-level interrupts rather than falling-edge interrupts, and whether flags should be specified is up the interrupt controller's DT binding. Signed-off-by: Jonathan Neuschäfer <j.neuschaefer@gmx.net> Acked-by: Rob Herring <robh@kernel.org> Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org> Link: https://lore.kernel.org/r/20210108163004.492649-1-j.neuschaefer@gmx.net