Thermal/int3403: Fix thermal hysteresis unit conversion
Thermal hysteresis represents a temperature difference. But the original code treats it as a temperature value, Convert it from tenths of degree Kelvin to Milli-Celsius by deducing 273200. This is not right. Kelvin and Celsius have same degree size. From temperature difference view, the conversion between tenths of degree Kelvin unit and Milli-Celsius unit is just to multiply 100. Signed-off-by: Lan Tianyu <tianyu.lan@intel.com> Acked-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com> Signed-off-by: Zhang Rui <rui.zhang@intel.com> Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
This commit is contained in:
parent
a1cff6e25e
commit
225112a569
@ -92,7 +92,13 @@ static int sys_get_trip_hyst(struct thermal_zone_device *tzone,
|
||||
if (ACPI_FAILURE(status))
|
||||
return -EIO;
|
||||
|
||||
*temp = DECI_KELVIN_TO_MILLI_CELSIUS(hyst, KELVIN_OFFSET);
|
||||
/*
|
||||
* Thermal hysteresis represents a temperature difference.
|
||||
* Kelvin and Celsius have same degree size. So the
|
||||
* conversion here between tenths of degree Kelvin unit
|
||||
* and Milli-Celsius unit is just to multiply 100.
|
||||
*/
|
||||
*temp = hyst * 100;
|
||||
|
||||
return 0;
|
||||
}
|
||||
|