hwmon: (scpi-hwmon) shows the negative temperature properly
The scpi hwmon shows the sub-zero temperature in an unsigned integer, which would confuse the users when the machine works in low temperature environment. This shows the sub-zero temperature in an signed value and users can get it properly from sensors. Signed-off-by: Riwen Lu <luriwen@kylinos.cn> Tested-by: Xin Chen <chenxin@kylinos.cn> Link: https://lore.kernel.org/r/20210604030959.736379-1-luriwen@kylinos.cn Signed-off-by: Guenter Roeck <linux@roeck-us.net>
This commit is contained in:
parent
7656cd2177
commit
78d1355234
@ -99,6 +99,15 @@ scpi_show_sensor(struct device *dev, struct device_attribute *attr, char *buf)
|
||||
|
||||
scpi_scale_reading(&value, sensor);
|
||||
|
||||
/*
|
||||
* Temperature sensor values are treated as signed values based on
|
||||
* observation even though that is not explicitly specified, and
|
||||
* because an unsigned u64 temperature does not really make practical
|
||||
* sense especially when the temperature is below zero degrees Celsius.
|
||||
*/
|
||||
if (sensor->info.class == TEMPERATURE)
|
||||
return sprintf(buf, "%lld\n", (s64)value);
|
||||
|
||||
return sprintf(buf, "%llu\n", value);
|
||||
}
|
||||
|
||||
|