mirror of
https://git.kernel.org/pub/scm/linux/kernel/git/stable/linux.git
synced 2025-01-08 14:13:53 +00:00
pwm: ftm: Correctly track usage count
No matter how many times the FTM PWM is enabled, the use_count will always be one. Signed-off-by: Xiubo Li <Li.Xiubo@freescale.com> Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
This commit is contained in:
parent
06e4cb6b1d
commit
8e6e765102
@ -299,7 +299,7 @@ static int fsl_counter_clock_enable(struct fsl_pwm_chip *fpc)
|
||||
{
|
||||
int ret;
|
||||
|
||||
if (fpc->use_count != 0)
|
||||
if (fpc->use_count++ != 0)
|
||||
return 0;
|
||||
|
||||
/* select counter clock source */
|
||||
@ -316,8 +316,6 @@ static int fsl_counter_clock_enable(struct fsl_pwm_chip *fpc)
|
||||
return ret;
|
||||
}
|
||||
|
||||
fpc->use_count++;
|
||||
|
||||
return 0;
|
||||
}
|
||||
|
||||
|
Loading…
Reference in New Issue
Block a user