power: supply: ingenic: Fix some error handling paths in ingenic_battery_get_property()

If iio_read_channel_processed() fails, 'val->intval' is not updated, but it
is still *1000 just after. So, in case of error, the *1000 accumulate and
'val->intval' becomes erroneous.

So instead of rescaling the value after the fact, use the dedicated scaling
API. This way the result is updated only when needed. In case of error, the
previous value is kept, unmodified.

This should also reduce any inaccuracies resulting from the scaling.

Finally, this is also slightly more efficient as it saves a function call
and a multiplication.

Fixes: fb24ccfbe1 ("power: supply: add Ingenic JZ47xx battery driver.")
Signed-off-by: Christophe JAILLET <christophe.jaillet@wanadoo.fr>
Acked-by: Artur Rojek <contact@artur-rojek.eu>
Link: https://lore.kernel.org/r/51e49c18574003db1e20c9299061a5ecd1661a3c.1719121781.git.christophe.jaillet@wanadoo.fr
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
This commit is contained in:
Christophe JAILLET 2024-06-23 07:50:32 +02:00 committed by Sebastian Reichel
parent f62b267adc
commit f8b6c1eb76

View File

@ -31,8 +31,9 @@ static int ingenic_battery_get_property(struct power_supply *psy,
switch (psp) {
case POWER_SUPPLY_PROP_HEALTH:
ret = iio_read_channel_processed(bat->channel, &val->intval);
val->intval *= 1000;
ret = iio_read_channel_processed_scale(bat->channel,
&val->intval,
1000);
if (val->intval < info->voltage_min_design_uv)
val->intval = POWER_SUPPLY_HEALTH_DEAD;
else if (val->intval > info->voltage_max_design_uv)
@ -41,8 +42,9 @@ static int ingenic_battery_get_property(struct power_supply *psy,
val->intval = POWER_SUPPLY_HEALTH_GOOD;
return ret;
case POWER_SUPPLY_PROP_VOLTAGE_NOW:
ret = iio_read_channel_processed(bat->channel, &val->intval);
val->intval *= 1000;
ret = iio_read_channel_processed_scale(bat->channel,
&val->intval,
1000);
return ret;
case POWER_SUPPLY_PROP_VOLTAGE_MIN_DESIGN:
val->intval = info->voltage_min_design_uv;