Sagi Grimberg 602d674ce9 nvme-tcp: support C2HData with SUCCESS flag
A C2HData PDU with the SUCCESS flag set indicates that the I/O was
completed by the controller successfully and means that a subsequent
completion response capsule PDU will be ommitted.

If we see this flag, fisrt we check that LAST_PDU flag is set as well,
and then we complete the request when the data transfer (and data digest
verification if its on) is done.

While we're at it, reuse a bit of code with nvme_fail_request.

Reported-by: Steve Blightman <steve.blightman@oracle.com>
Suggested-by: Oliver Smith-Denny <osmithde@cisco.com>
Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: Oliver Smith-Denny <osmithde@cisco.com>
Tested-by: Oliver Smith-Denny <osmithde@cisco.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Signed-off-by: Jens Axboe <axboe@kernel.dk>
2019-03-13 12:57:34 -06:00
..
2017-10-04 09:43:57 +02:00
2016-07-05 11:30:33 -06:00