Lukas Wunner dc76697d7e serial: 8250_bcm2835aux: Fix line mismatch on driver unbind
Unbinding the bcm2835aux UART driver raises the following error if the
maximum number of 8250 UARTs is set to 1 (via the 8250.nr_uarts module
parameter or CONFIG_SERIAL_8250_RUNTIME_UARTS):

(NULL device *): Removing wrong port: a6f80333 != fa20408b

That's because bcm2835aux_serial_probe() retrieves UART line number 1
from the devicetree and stores it in data->uart.port.line, while
serial8250_register_8250_port() instead uses UART line number 0,
which is stored in data->line.

On driver unbind, bcm2835aux_serial_remove() uses data->uart.port.line,
which contains the wrong number.  Fix it.

The issue does not occur if the maximum number of 8250 UARTs is >= 2.

Fixes: bdc5f3009580 ("serial: bcm2835: add driver for bcm2835-aux-uart")
Signed-off-by: Lukas Wunner <lukas@wunner.de>
Cc: stable@vger.kernel.org # v4.6+
Cc: Martin Sperl <kernel@martin.sperl.org>
Reviewed-by: Nicolas Saenz Julienne <nsaenzjulienne@suse.de>
Tested-by: Nicolas Saenz Julienne <nsaenzjulienne@suse.de>
Link: https://lore.kernel.org/r/912ccf553c5258135c6d7e8f404a101ef320f0f4.1579175223.git.lukas@wunner.de
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
2020-01-22 10:22:29 +01:00
..
2019-12-03 14:09:14 -08:00
2020-01-13 12:13:05 +01:00
2019-11-13 19:01:14 +08:00
2019-04-16 15:21:34 +02:00
2018-10-13 00:50:32 -04:00
2017-11-28 15:32:33 +01:00
2018-10-13 00:50:32 -04:00
2019-10-04 15:14:20 +02:00
2017-11-08 13:08:12 +01:00
2019-09-04 12:43:44 +02:00
2019-11-04 17:42:28 +01:00
2019-02-12 08:51:33 +01:00
2019-12-17 14:46:23 +01:00
2019-12-30 19:34:44 +01:00
2019-04-16 15:21:34 +02:00