linux/drivers/thermal/thermal_thresholds.h

20 lines
789 B
C
Raw Permalink Normal View History

thermal: core: Add user thresholds support The user thresholds mechanism is a way to have the userspace to tell the thermal framework to send a notification when a temperature limit is crossed. There is no id, no hysteresis, just the temperature and the direction of the limit crossing. That means we can be notified when a threshold is crossed the way up only, or the way down only or both ways. That allows to create hysteresis values if it is needed. A threshold can be added, deleted or flushed. The latter means all thresholds belonging to a thermal zone will be deleted. When a threshold is added: - if the same threshold (temperature and direction) exists, an error is returned - if a threshold is specified with the same temperature but a different direction, the specified direction is added - if there is no threshold with the same temperature then it is created When a threshold is deleted: - if the same threshold (temperature and direction) exists, it is deleted - if a threshold is specified with the same temperature but a different direction, the specified direction is removed - if there is no threshold with the same temperature, then an error is returned When the threshold are flushed: - All thresholds related to a thermal zone are deleted When a threshold is crossed: - the userspace does not need to know which threshold(s) have been crossed, it will be notified with the current temperature and the previous temperature - if multiple thresholds have been crossed between two updates only one notification will be send to the userspace, it is pointless to send a notification per thresholds crossed as the userspace can handle that easily when it has the temperature delta information Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org> Link: https://patch.msgid.link/20240923100005.2532430-2-daniel.lezcano@linaro.org [ rjw: Subject edit, use BIT(0) and BIT(1) in symbol definitions ] Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
2024-09-23 09:59:57 +00:00
/* SPDX-License-Identifier: GPL-2.0 */
#ifndef __THERMAL_THRESHOLDS_H__
#define __THERMAL_THRESHOLDS_H__
struct user_threshold {
struct list_head list_node;
int temperature;
int direction;
};
int thermal_thresholds_init(struct thermal_zone_device *tz);
void thermal_thresholds_exit(struct thermal_zone_device *tz);
void thermal_thresholds_handle(struct thermal_zone_device *tz, int *low, int *high);
void thermal_thresholds_flush(struct thermal_zone_device *tz);
thermal: core: Add user thresholds support The user thresholds mechanism is a way to have the userspace to tell the thermal framework to send a notification when a temperature limit is crossed. There is no id, no hysteresis, just the temperature and the direction of the limit crossing. That means we can be notified when a threshold is crossed the way up only, or the way down only or both ways. That allows to create hysteresis values if it is needed. A threshold can be added, deleted or flushed. The latter means all thresholds belonging to a thermal zone will be deleted. When a threshold is added: - if the same threshold (temperature and direction) exists, an error is returned - if a threshold is specified with the same temperature but a different direction, the specified direction is added - if there is no threshold with the same temperature then it is created When a threshold is deleted: - if the same threshold (temperature and direction) exists, it is deleted - if a threshold is specified with the same temperature but a different direction, the specified direction is removed - if there is no threshold with the same temperature, then an error is returned When the threshold are flushed: - All thresholds related to a thermal zone are deleted When a threshold is crossed: - the userspace does not need to know which threshold(s) have been crossed, it will be notified with the current temperature and the previous temperature - if multiple thresholds have been crossed between two updates only one notification will be send to the userspace, it is pointless to send a notification per thresholds crossed as the userspace can handle that easily when it has the temperature delta information Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org> Link: https://patch.msgid.link/20240923100005.2532430-2-daniel.lezcano@linaro.org [ rjw: Subject edit, use BIT(0) and BIT(1) in symbol definitions ] Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
2024-09-23 09:59:57 +00:00
int thermal_thresholds_add(struct thermal_zone_device *tz, int temperature, int direction);
int thermal_thresholds_delete(struct thermal_zone_device *tz, int temperature, int direction);
int thermal_thresholds_for_each(struct thermal_zone_device *tz,
int (*cb)(struct user_threshold *, void *arg), void *arg);
#endif