mirror of
https://git.kernel.org/pub/scm/linux/kernel/git/torvalds/linux.git
synced 2025-01-01 02:33:57 +00:00
iio: chemical: bme680: Fix pressure value output
The IIO standard units are measured in kPa while the driver
is using hPa.
Apart from checking the userspace value itself, it is mentioned also
in the Bosch API [1] that the pressure value is in Pascal.
[1]: https://github.com/boschsensortec/BME68x_SensorAPI/blob/v4.4.8/bme68x_defs.h#L742
Fixes: 1b3bd85927
("iio: chemical: Add support for Bosch BME680 sensor")
Signed-off-by: Vasileios Amoiridis <vassilisamir@gmail.com>
Link: https://lore.kernel.org/r/20240606212313.207550-2-vassilisamir@gmail.com
Cc: <Stable@vger.kernel.org>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
This commit is contained in:
parent
9547d6a4c6
commit
ae1f7b93b5
@ -678,7 +678,7 @@ static int bme680_read_press(struct bme680_data *data,
|
||||
}
|
||||
|
||||
*val = bme680_compensate_press(data, adc_press);
|
||||
*val2 = 100;
|
||||
*val2 = 1000;
|
||||
return IIO_VAL_FRACTIONAL;
|
||||
}
|
||||
|
||||
|
Loading…