rtc: ab-eoz9: don't fail temperature reads on undervoltage notification

The undervoltage flags reported by the RTC are useful to know if the
time and date are reliable after a reboot. Although the threshold VLOW1
indicates that the thermometer has been shutdown and time compensation
is off, it doesn't mean that the temperature readout is currently
impossible.

As the system is running, the RTC voltage is now fully established and
we can read the temperature.

Fixes: 67075b63cc ("rtc: add AB-RTCMC-32.768kHz-EOZ9 RTC support")
Signed-off-by: Maxime Chevallier <maxime.chevallier@bootlin.com>
Link: https://lore.kernel.org/r/20241122101031.68916-3-maxime.chevallier@bootlin.com
Signed-off-by: Alexandre Belloni <alexandre.belloni@bootlin.com>
This commit is contained in:
Maxime Chevallier 2024-11-22 11:10:30 +01:00 committed by Alexandre Belloni
parent 3ed345c948
commit e0779a0dcf

View File

@ -394,13 +394,6 @@ static int abeoz9z3_temp_read(struct device *dev,
if (ret < 0)
return ret;
if ((val & ABEOZ9_REG_CTRL_STATUS_V1F) ||
(val & ABEOZ9_REG_CTRL_STATUS_V2F)) {
dev_err(dev,
"thermometer might be disabled due to low voltage\n");
return -EINVAL;
}
switch (attr) {
case hwmon_temp_input:
ret = regmap_read(regmap, ABEOZ9_REG_REG_TEMP, &val);