Webb Scales 0d96ef5ff4 hpsa: clean up host, channel, target, lun prints
We had a mix of formats used for specifying controller, bus, target,
and lun address of devices.

change to the format used by the scsi midlayer and upper layer (2:3:0:0)
so you can easily follow the information from hpsa to scsi midlayer
to sd upper layer.

Also add this information:
- product ID
- vendor ID
- RAID level
- SSD Smath Path capable and enabled
- exposure level (sg-only)

Example:
hpsa 0000:04:00.0: added scsi 2:0:0:0: Direct-Access     HP LOGICAL VOLUME   RAID-0 SSDSmartPathCap+ En+ Exp=4
scsi 2:0:0:0: Direct-Access     HP       LOGICAL VOLUME   10.0 PQ: 0 ANSI: 5
sd 2:0:0:0: [sdr] 12501713072 512-byte logical blocks: (6.40 TB/5.82 TiB)
sd 2:0:0:0: [sdr] 4096-byte physical blocks
sd 2:0:0:0: [sdr] Attached SCSI disk
sd 2:0:0:0: Attached scsi generic sg20 type 0

Reviewed-by: Scott Teel <scott.teel@pmcs.com>
Reviewed-by: Kevin Barnett <kevin.barnett@pmcs.com>
Reviewed-by: Tomas Henzl <thenzl@redhat.com>
Reviewed-by: Hannes Reinecke <hare@Suse.de>
Signed-off-by: Robert Elliott <elliott@hp.com>
Signed-off-by: Don Brace <don.brace@pmcs.com>
Reviewed-by: Christoph Hellwig <hch@lst.de>
Signed-off-by: James Bottomley <JBottomley@Odin.com>
2015-05-31 11:21:15 -07:00
..
2015-04-16 13:53:32 -05:00
2015-04-22 09:18:17 -07:00
2015-04-21 09:42:58 -07:00
2015-04-22 09:03:30 -07:00
2015-04-22 09:18:17 -07:00
2015-04-22 09:04:39 -07:00
2015-04-17 15:32:07 -04:00
2015-04-26 13:36:02 -07:00
2015-04-24 08:23:45 -07:00
2015-04-24 09:28:01 -07:00
2015-04-22 09:18:17 -07:00
2015-04-26 13:36:02 -07:00
2015-04-21 09:42:58 -07:00
2015-04-07 12:05:12 +02:00
2015-04-24 08:46:18 -07:00
2015-04-16 14:01:03 -05:00
2015-04-22 09:04:39 -07:00
2015-04-13 17:07:21 -07:00
2015-04-15 10:02:42 +02:00
2015-04-26 13:44:46 -07:00
2015-03-31 12:01:19 -04:00
2015-04-24 08:46:18 -07:00
2015-04-08 08:11:51 -06:00
2015-04-20 15:16:25 -07:00
2015-03-25 12:25:29 +01:00