Dmitry Rokosov b6ec400aa1 clk: meson: introduce new pll power-on sequence for A1 SoC family
Modern meson PLL IPs are a little bit different from early known PLLs.
The main difference is located in the init/enable/disable sequences; the
rate logic is the same.

In A1 PLL, the PLL enable sequence is different, so add new optional pll
reg bits and use the new power-on sequence to enable the PLL:
    1. enable the pll, delay for 10us
    2. enable the pll self-adaption current module, delay for 40us
    3. enable the lock detect module

Signed-off-by: Jian Hu <jian.hu@amlogic.com>
Acked-by: Martin Blumenstingl <martin.blumenstingl@googlemail.com>
Signed-off-by: Dmitry Rokosov <ddrokosov@sberdevices.ru>
Link: https://lore.kernel.org/r/20230523135351.19133-3-ddrokosov@sberdevices.ru
Signed-off-by: Jerome Brunet <jbrunet@baylibre.com>
2023-05-30 17:53:00 +02:00
..
2020-08-17 15:58:02 +02:00
2020-08-17 15:58:02 +02:00
2020-11-23 09:08:23 +01:00