mirror of
https://git.kernel.org/pub/scm/linux/kernel/git/next/linux-next.git
synced 2025-01-04 04:02:26 +00:00
thermal/drivers/cpu_cooling: Rename to cpufreq_cooling
As we introduced the idle injection cooling device called cpuidle_cooling, let's be consistent and rename the cpu_cooling to cpufreq_cooling as this one mitigates with OPPs changes. Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org> Acked-by: Viresh Kumar <viresh.kumar@linaro.org> Reviewed-by: Amit Kucheria <amit.kucheria@linaro.org> Link: https://lore.kernel.org/r/20191219225317.17158-3-daniel.lezcano@linaro.org
This commit is contained in:
parent
a4c428e523
commit
23affa2e29
@ -67,7 +67,7 @@ TMU driver description:
|
|||||||
The exynos thermal driver is structured as::
|
The exynos thermal driver is structured as::
|
||||||
|
|
||||||
Kernel Core thermal framework
|
Kernel Core thermal framework
|
||||||
(thermal_core.c, step_wise.c, cpu_cooling.c)
|
(thermal_core.c, step_wise.c, cpufreq_cooling.c)
|
||||||
^
|
^
|
||||||
|
|
|
|
||||||
|
|
|
|
||||||
|
@ -16349,7 +16349,7 @@ L: linux-pm@vger.kernel.org
|
|||||||
S: Supported
|
S: Supported
|
||||||
F: Documentation/driver-api/thermal/cpu-cooling-api.rst
|
F: Documentation/driver-api/thermal/cpu-cooling-api.rst
|
||||||
F: Documentation/driver-api/thermal/cpu-idle-cooling.rst
|
F: Documentation/driver-api/thermal/cpu-idle-cooling.rst
|
||||||
F: drivers/thermal/cpu_cooling.c
|
F: drivers/thermal/cpufreq_cooling.c
|
||||||
F: drivers/thermal/cpuidle_cooling.c
|
F: drivers/thermal/cpuidle_cooling.c
|
||||||
F: include/linux/cpu_cooling.h
|
F: include/linux/cpu_cooling.h
|
||||||
|
|
||||||
|
@ -19,7 +19,7 @@ thermal_sys-$(CONFIG_THERMAL_GOV_USER_SPACE) += user_space.o
|
|||||||
thermal_sys-$(CONFIG_THERMAL_GOV_POWER_ALLOCATOR) += power_allocator.o
|
thermal_sys-$(CONFIG_THERMAL_GOV_POWER_ALLOCATOR) += power_allocator.o
|
||||||
|
|
||||||
# cpufreq cooling
|
# cpufreq cooling
|
||||||
thermal_sys-$(CONFIG_CPU_FREQ_THERMAL) += cpu_cooling.o
|
thermal_sys-$(CONFIG_CPU_FREQ_THERMAL) += cpufreq_cooling.o
|
||||||
thermal_sys-$(CONFIG_CPU_IDLE_THERMAL) += cpuidle_cooling.o
|
thermal_sys-$(CONFIG_CPU_IDLE_THERMAL) += cpuidle_cooling.o
|
||||||
|
|
||||||
# clock cooling
|
# clock cooling
|
||||||
|
@ -7,7 +7,7 @@
|
|||||||
* Copyright (C) 2013 Texas Instruments Inc.
|
* Copyright (C) 2013 Texas Instruments Inc.
|
||||||
* Contact: Eduardo Valentin <eduardo.valentin@ti.com>
|
* Contact: Eduardo Valentin <eduardo.valentin@ti.com>
|
||||||
*
|
*
|
||||||
* Highly based on cpu_cooling.c.
|
* Highly based on cpufreq_cooling.c.
|
||||||
* Copyright (C) 2012 Samsung Electronics Co., Ltd(http://www.samsung.com)
|
* Copyright (C) 2012 Samsung Electronics Co., Ltd(http://www.samsung.com)
|
||||||
* Copyright (C) 2012 Amit Daniel <amit.kachhap@linaro.org>
|
* Copyright (C) 2012 Amit Daniel <amit.kachhap@linaro.org>
|
||||||
*/
|
*/
|
||||||
|
@ -1,6 +1,6 @@
|
|||||||
// SPDX-License-Identifier: GPL-2.0
|
// SPDX-License-Identifier: GPL-2.0
|
||||||
/*
|
/*
|
||||||
* linux/drivers/thermal/cpu_cooling.c
|
* linux/drivers/thermal/cpufreq_cooling.c
|
||||||
*
|
*
|
||||||
* Copyright (C) 2012 Samsung Electronics Co., Ltd(http://www.samsung.com)
|
* Copyright (C) 2012 Samsung Electronics Co., Ltd(http://www.samsung.com)
|
||||||
*
|
*
|
||||||
@ -621,7 +621,7 @@ of_cpufreq_cooling_register(struct cpufreq_policy *policy)
|
|||||||
struct thermal_cooling_device *cdev = NULL;
|
struct thermal_cooling_device *cdev = NULL;
|
||||||
|
|
||||||
if (!np) {
|
if (!np) {
|
||||||
pr_err("cpu_cooling: OF node not available for cpu%d\n",
|
pr_err("cpufreq_cooling: OF node not available for cpu%d\n",
|
||||||
policy->cpu);
|
policy->cpu);
|
||||||
return NULL;
|
return NULL;
|
||||||
}
|
}
|
||||||
@ -631,7 +631,7 @@ of_cpufreq_cooling_register(struct cpufreq_policy *policy)
|
|||||||
|
|
||||||
cdev = __cpufreq_cooling_register(np, policy, em);
|
cdev = __cpufreq_cooling_register(np, policy, em);
|
||||||
if (IS_ERR(cdev)) {
|
if (IS_ERR(cdev)) {
|
||||||
pr_err("cpu_cooling: cpu%d failed to register as cooling device: %ld\n",
|
pr_err("cpufreq_cooling: cpu%d failed to register as cooling device: %ld\n",
|
||||||
policy->cpu, PTR_ERR(cdev));
|
policy->cpu, PTR_ERR(cdev));
|
||||||
cdev = NULL;
|
cdev = NULL;
|
||||||
}
|
}
|
@ -7,7 +7,7 @@
|
|||||||
* Copyright (C) 2013 Texas Instruments Inc.
|
* Copyright (C) 2013 Texas Instruments Inc.
|
||||||
* Contact: Eduardo Valentin <eduardo.valentin@ti.com>
|
* Contact: Eduardo Valentin <eduardo.valentin@ti.com>
|
||||||
*
|
*
|
||||||
* Highly based on cpu_cooling.c.
|
* Highly based on cpufreq_cooling.c.
|
||||||
* Copyright (C) 2012 Samsung Electronics Co., Ltd(http://www.samsung.com)
|
* Copyright (C) 2012 Samsung Electronics Co., Ltd(http://www.samsung.com)
|
||||||
* Copyright (C) 2012 Amit Daniel <amit.kachhap@linaro.org>
|
* Copyright (C) 2012 Amit Daniel <amit.kachhap@linaro.org>
|
||||||
*/
|
*/
|
||||||
|
Loading…
Reference in New Issue
Block a user