Akinobu Mita 73e3e3fc50 iio: adc: ti-ads1015: avoid getting stale result after runtime resume
This driver assumes that the device is operating in the continuous
conversion mode which performs the conversion continuously.  So this driver
doesn't insert a wait time before reading the conversion register if the
configuration is not changed from a previous request.

This assumption is broken if the device is runtime suspended and entered
a power-down state.  The forthcoming request causes reading a stale result
from the conversion register as the device is runtime resumed just before.

Fix it by adding a flag to detect that condition and insert a necessary
wait time.

Cc: Daniel Baluta <daniel.baluta@gmail.com>
Signed-off-by: Akinobu Mita <akinobu.mita@gmail.com>
Cc: <Stable@vger.kernel.org>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2017-08-20 15:41:13 +01:00
..
2015-11-05 13:15:12 -08:00