hwmon: (mlxreg-fan) Extend number of supported fans

Some new big modular systems can be equipped with up to 24 fans.
Extend maximum number of fans accordingly.

Signed-off-by: Vadim Pasternak <vadimp@nvidia.com>
Link: https://lore.kernel.org/r/20230824164006.26868-1-vadimp@nvidia.com
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
This commit is contained in:
Vadim Pasternak 2023-08-24 16:40:06 +00:00 committed by Guenter Roeck
parent a1f38987dd
commit dadca53dd9

View File

@ -12,7 +12,7 @@
#include <linux/regmap.h>
#include <linux/thermal.h>
#define MLXREG_FAN_MAX_TACHO 14
#define MLXREG_FAN_MAX_TACHO 24
#define MLXREG_FAN_MAX_PWM 4
#define MLXREG_FAN_PWM_NOT_CONNECTED 0xff
#define MLXREG_FAN_MAX_STATE 10
@ -300,6 +300,16 @@ static const struct hwmon_channel_info * const mlxreg_fan_hwmon_info[] = {
HWMON_F_INPUT | HWMON_F_FAULT,
HWMON_F_INPUT | HWMON_F_FAULT,
HWMON_F_INPUT | HWMON_F_FAULT,
HWMON_F_INPUT | HWMON_F_FAULT,
HWMON_F_INPUT | HWMON_F_FAULT,
HWMON_F_INPUT | HWMON_F_FAULT,
HWMON_F_INPUT | HWMON_F_FAULT,
HWMON_F_INPUT | HWMON_F_FAULT,
HWMON_F_INPUT | HWMON_F_FAULT,
HWMON_F_INPUT | HWMON_F_FAULT,
HWMON_F_INPUT | HWMON_F_FAULT,
HWMON_F_INPUT | HWMON_F_FAULT,
HWMON_F_INPUT | HWMON_F_FAULT,
HWMON_F_INPUT | HWMON_F_FAULT),
HWMON_CHANNEL_INFO(pwm,
HWMON_PWM_INPUT,