power: supply: adp5061: show unknown capacity_level as text

adp5061_get_battery_status() only defined show chg_status <= 4, others will
be show as '-1731902199' from /sys/class/power_supply/xx/capacity_level.
switch to show them as 'Unknown'.

Signed-off-by: Wei Yongjun <weiyongjun1@huawei.com>
Acked-by: Michael Hennerich <michael.hennerich@analog.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
This commit is contained in:
Wei Yongjun 2022-08-27 07:32:24 +00:00 committed by Sebastian Reichel
parent 9d47e01b9d
commit e568252d72

View File

@ -493,6 +493,9 @@ static int adp5061_get_battery_status(struct adp5061_state *st,
case 0x4: /* VBAT_SNS > VWEAK */
val->intval = POWER_SUPPLY_CAPACITY_LEVEL_NORMAL;
break;
default:
val->intval = POWER_SUPPLY_CAPACITY_LEVEL_UNKNOWN;
break;
}
return ret;