mirror of
https://git.kernel.org/pub/scm/linux/kernel/git/stable/linux.git
synced 2024-12-29 17:25:38 +00:00
d679783188
explicitly specify the flag if there's a valid reason to show it in /proc/cpuinfo - Switch a bunch of Intel x86 model checking code to the new CPU model defines - Fixes and cleanups -----BEGIN PGP SIGNATURE----- iQIzBAABCgAdFiEEzv7L6UO9uDPlPSfHEsHwGGHeVUoFAmaVZ+EACgkQEsHwGGHe VUqTgA//aJez6C5SmuqIofqgimr+8JGNThf4vFB3O9tN0ony3IR8IRieF+sOZFXE WVyN7KOhPs2XvNzVAaJpzWUcg/E2bXzVrOKfx3uFiyNiBttKLVot7Hl640wqWGoG eTViTpQ6IALY7lEI6vFNXz+4Ja5PWmHxWdBkvP9ehSvqNxHivTWL4HQ11pcCWQEA i+V37PbOHsnH7ZprJtaV0ihtjFblk9/R4qoZuT3SObhG0QDJK4Q7yYUelxXMUUgD Yo3nXluQl6Vc5dD2ULYkTlhzMxoZUMURty897vYSsZz49ZXsS6fsvd+BheSQVOv1 hzaqqFYijdIpPI1zwgAPM+e6S/EAafpNVcEkjhHGZIJehwXm3teoSlX5tK2NPGoe PLYrwPWAzagdS3dWvrvBYT3Bu7pygieDSyPFfVP2XQsElHsWhYvBtxeH/uUwm+v4 xjtXaJUj9eznChPaDZhCl8ioh9szUKHsh2NJ5ND7qpxPCFpz1Xj9ZmbIYTjHEgjG IT8dFfykKdyh5htJWw/P8LbexpEMTmu/LDrDXt+tFsDLBKIkeLiP3h8+yDR+vJ7K OGBjY2ciSi9Wy9ynunCOCNHNBdia1qc3AJWSg/2YP4NW+RzRLe6cIs+Ih4s1N5lx ADvw+TA9CAKo1KASyOVYAxq7h4xlsyH6jbCC3ZW3P/a+Bs8smqM= =SEED -----END PGP SIGNATURE----- Merge tag 'x86_cpu_for_v6.11_rc1' of git://git.kernel.org/pub/scm/linux/kernel/git/tip/tip Pull x86 cpu model updates from Borislav Petkov: - Flip the logic to add feature names to /proc/cpuinfo to having to explicitly specify the flag if there's a valid reason to show it in /proc/cpuinfo - Switch a bunch of Intel x86 model checking code to the new CPU model defines - Fixes and cleanups * tag 'x86_cpu_for_v6.11_rc1' of git://git.kernel.org/pub/scm/linux/kernel/git/tip/tip: x86/cpu/intel: Drop stray FAM6 check with new Intel CPU model defines x86/cpufeatures: Flip the /proc/cpuinfo appearance logic x86/CPU/AMD: Always inline amd_clear_divider() x86/mce/inject: Add missing MODULE_DESCRIPTION() line perf/x86/rapl: Switch to new Intel CPU model defines x86/boot: Switch to new Intel CPU model defines x86/cpu: Switch to new Intel CPU model defines perf/x86/intel: Switch to new Intel CPU model defines x86/virt/tdx: Switch to new Intel CPU model defines x86/PCI: Switch to new Intel CPU model defines x86/cpu/intel: Switch to new Intel CPU model defines x86/platform/intel-mid: Switch to new Intel CPU model defines x86/pconfig: Remove unused MKTME pconfig code x86/cpu: Remove useless work in detect_tme_early()
407 lines
11 KiB
C
407 lines
11 KiB
C
// SPDX-License-Identifier: GPL-2.0
|
|
/*
|
|
* Intel MID PCI support
|
|
* Copyright (c) 2008 Intel Corporation
|
|
* Jesse Barnes <jesse.barnes@intel.com>
|
|
*
|
|
* Moorestown has an interesting PCI implementation:
|
|
* - configuration space is memory mapped (as defined by MCFG)
|
|
* - Lincroft devices also have a real, type 1 configuration space
|
|
* - Early Lincroft silicon has a type 1 access bug that will cause
|
|
* a hang if non-existent devices are accessed
|
|
* - some devices have the "fixed BAR" capability, which means
|
|
* they can't be relocated or modified; check for that during
|
|
* BAR sizing
|
|
*
|
|
* So, we use the MCFG space for all reads and writes, but also send
|
|
* Lincroft writes to type 1 space. But only read/write if the device
|
|
* actually exists, otherwise return all 1s for reads and bit bucket
|
|
* the writes.
|
|
*/
|
|
|
|
#include <linux/sched.h>
|
|
#include <linux/pci.h>
|
|
#include <linux/ioport.h>
|
|
#include <linux/init.h>
|
|
#include <linux/dmi.h>
|
|
#include <linux/acpi.h>
|
|
#include <linux/io.h>
|
|
#include <linux/smp.h>
|
|
|
|
#include <asm/cpu_device_id.h>
|
|
#include <asm/segment.h>
|
|
#include <asm/pci_x86.h>
|
|
#include <asm/hw_irq.h>
|
|
#include <asm/io_apic.h>
|
|
#include <asm/intel-family.h>
|
|
#include <asm/intel-mid.h>
|
|
#include <asm/acpi.h>
|
|
|
|
#define PCIE_CAP_OFFSET 0x100
|
|
|
|
/* Quirks for the listed devices */
|
|
#define PCI_DEVICE_ID_INTEL_MRFLD_MMC 0x1190
|
|
#define PCI_DEVICE_ID_INTEL_MRFLD_HSU 0x1191
|
|
|
|
/* Fixed BAR fields */
|
|
#define PCIE_VNDR_CAP_ID_FIXED_BAR 0x00 /* Fixed BAR (TBD) */
|
|
#define PCI_FIXED_BAR_0_SIZE 0x04
|
|
#define PCI_FIXED_BAR_1_SIZE 0x08
|
|
#define PCI_FIXED_BAR_2_SIZE 0x0c
|
|
#define PCI_FIXED_BAR_3_SIZE 0x10
|
|
#define PCI_FIXED_BAR_4_SIZE 0x14
|
|
#define PCI_FIXED_BAR_5_SIZE 0x1c
|
|
|
|
static int pci_soc_mode;
|
|
|
|
/**
|
|
* fixed_bar_cap - return the offset of the fixed BAR cap if found
|
|
* @bus: PCI bus
|
|
* @devfn: device in question
|
|
*
|
|
* Look for the fixed BAR cap on @bus and @devfn, returning its offset
|
|
* if found or 0 otherwise.
|
|
*/
|
|
static int fixed_bar_cap(struct pci_bus *bus, unsigned int devfn)
|
|
{
|
|
int pos;
|
|
u32 pcie_cap = 0, cap_data;
|
|
|
|
pos = PCIE_CAP_OFFSET;
|
|
|
|
if (!raw_pci_ext_ops)
|
|
return 0;
|
|
|
|
while (pos) {
|
|
if (raw_pci_ext_ops->read(pci_domain_nr(bus), bus->number,
|
|
devfn, pos, 4, &pcie_cap))
|
|
return 0;
|
|
|
|
if (PCI_EXT_CAP_ID(pcie_cap) == 0x0000 ||
|
|
PCI_EXT_CAP_ID(pcie_cap) == 0xffff)
|
|
break;
|
|
|
|
if (PCI_EXT_CAP_ID(pcie_cap) == PCI_EXT_CAP_ID_VNDR) {
|
|
raw_pci_ext_ops->read(pci_domain_nr(bus), bus->number,
|
|
devfn, pos + 4, 4, &cap_data);
|
|
if ((cap_data & 0xffff) == PCIE_VNDR_CAP_ID_FIXED_BAR)
|
|
return pos;
|
|
}
|
|
|
|
pos = PCI_EXT_CAP_NEXT(pcie_cap);
|
|
}
|
|
|
|
return 0;
|
|
}
|
|
|
|
static int pci_device_update_fixed(struct pci_bus *bus, unsigned int devfn,
|
|
int reg, int len, u32 val, int offset)
|
|
{
|
|
u32 size;
|
|
unsigned int domain, busnum;
|
|
int bar = (reg - PCI_BASE_ADDRESS_0) >> 2;
|
|
|
|
domain = pci_domain_nr(bus);
|
|
busnum = bus->number;
|
|
|
|
if (val == ~0 && len == 4) {
|
|
unsigned long decode;
|
|
|
|
raw_pci_ext_ops->read(domain, busnum, devfn,
|
|
offset + 8 + (bar * 4), 4, &size);
|
|
|
|
/* Turn the size into a decode pattern for the sizing code */
|
|
if (size) {
|
|
decode = size - 1;
|
|
decode |= decode >> 1;
|
|
decode |= decode >> 2;
|
|
decode |= decode >> 4;
|
|
decode |= decode >> 8;
|
|
decode |= decode >> 16;
|
|
decode++;
|
|
decode = ~(decode - 1);
|
|
} else {
|
|
decode = 0;
|
|
}
|
|
|
|
/*
|
|
* If val is all ones, the core code is trying to size the reg,
|
|
* so update the mmconfig space with the real size.
|
|
*
|
|
* Note: this assumes the fixed size we got is a power of two.
|
|
*/
|
|
return raw_pci_ext_ops->write(domain, busnum, devfn, reg, 4,
|
|
decode);
|
|
}
|
|
|
|
/* This is some other kind of BAR write, so just do it. */
|
|
return raw_pci_ext_ops->write(domain, busnum, devfn, reg, len, val);
|
|
}
|
|
|
|
/**
|
|
* type1_access_ok - check whether to use type 1
|
|
* @bus: bus number
|
|
* @devfn: device & function in question
|
|
* @reg: configuration register offset
|
|
*
|
|
* If the bus is on a Lincroft chip and it exists, or is not on a Lincroft at
|
|
* all, the we can go ahead with any reads & writes. If it's on a Lincroft,
|
|
* but doesn't exist, avoid the access altogether to keep the chip from
|
|
* hanging.
|
|
*/
|
|
static bool type1_access_ok(unsigned int bus, unsigned int devfn, int reg)
|
|
{
|
|
/*
|
|
* This is a workaround for A0 LNC bug where PCI status register does
|
|
* not have new CAP bit set. can not be written by SW either.
|
|
*
|
|
* PCI header type in real LNC indicates a single function device, this
|
|
* will prevent probing other devices under the same function in PCI
|
|
* shim. Therefore, use the header type in shim instead.
|
|
*/
|
|
if (reg >= 0x100 || reg == PCI_STATUS || reg == PCI_HEADER_TYPE)
|
|
return false;
|
|
if (bus == 0 && (devfn == PCI_DEVFN(2, 0)
|
|
|| devfn == PCI_DEVFN(0, 0)
|
|
|| devfn == PCI_DEVFN(3, 0)))
|
|
return true;
|
|
return false; /* Langwell on others */
|
|
}
|
|
|
|
static int pci_read(struct pci_bus *bus, unsigned int devfn, int where,
|
|
int size, u32 *value)
|
|
{
|
|
if (type1_access_ok(bus->number, devfn, where))
|
|
return pci_direct_conf1.read(pci_domain_nr(bus), bus->number,
|
|
devfn, where, size, value);
|
|
return raw_pci_ext_ops->read(pci_domain_nr(bus), bus->number,
|
|
devfn, where, size, value);
|
|
}
|
|
|
|
static int pci_write(struct pci_bus *bus, unsigned int devfn, int where,
|
|
int size, u32 value)
|
|
{
|
|
int offset;
|
|
|
|
/*
|
|
* On MRST, there is no PCI ROM BAR, this will cause a subsequent read
|
|
* to ROM BAR return 0 then being ignored.
|
|
*/
|
|
if (where == PCI_ROM_ADDRESS)
|
|
return 0;
|
|
|
|
/*
|
|
* Devices with fixed BARs need special handling:
|
|
* - BAR sizing code will save, write ~0, read size, restore
|
|
* - so writes to fixed BARs need special handling
|
|
* - other writes to fixed BAR devices should go through mmconfig
|
|
*/
|
|
offset = fixed_bar_cap(bus, devfn);
|
|
if (offset &&
|
|
(where >= PCI_BASE_ADDRESS_0 && where <= PCI_BASE_ADDRESS_5)) {
|
|
return pci_device_update_fixed(bus, devfn, where, size, value,
|
|
offset);
|
|
}
|
|
|
|
/*
|
|
* On Moorestown update both real & mmconfig space
|
|
* Note: early Lincroft silicon can't handle type 1 accesses to
|
|
* non-existent devices, so just eat the write in that case.
|
|
*/
|
|
if (type1_access_ok(bus->number, devfn, where))
|
|
return pci_direct_conf1.write(pci_domain_nr(bus), bus->number,
|
|
devfn, where, size, value);
|
|
return raw_pci_ext_ops->write(pci_domain_nr(bus), bus->number, devfn,
|
|
where, size, value);
|
|
}
|
|
|
|
static const struct x86_cpu_id intel_mid_cpu_ids[] = {
|
|
X86_MATCH_VFM(INTEL_ATOM_SILVERMONT_MID, NULL),
|
|
{}
|
|
};
|
|
|
|
static int intel_mid_pci_irq_enable(struct pci_dev *dev)
|
|
{
|
|
const struct x86_cpu_id *id;
|
|
struct irq_alloc_info info;
|
|
bool polarity_low;
|
|
u16 model = 0;
|
|
int ret;
|
|
u8 gsi;
|
|
|
|
if (dev->irq_managed && dev->irq > 0)
|
|
return 0;
|
|
|
|
ret = pci_read_config_byte(dev, PCI_INTERRUPT_LINE, &gsi);
|
|
if (ret) {
|
|
dev_warn(&dev->dev, "Failed to read interrupt line: %d\n", ret);
|
|
return pcibios_err_to_errno(ret);
|
|
}
|
|
|
|
id = x86_match_cpu(intel_mid_cpu_ids);
|
|
if (id)
|
|
model = id->model;
|
|
|
|
switch (model) {
|
|
case VFM_MODEL(INTEL_ATOM_SILVERMONT_MID):
|
|
polarity_low = false;
|
|
|
|
/* Special treatment for IRQ0 */
|
|
if (gsi == 0) {
|
|
/*
|
|
* Skip HS UART common registers device since it has
|
|
* IRQ0 assigned and not used by the kernel.
|
|
*/
|
|
if (dev->device == PCI_DEVICE_ID_INTEL_MRFLD_HSU)
|
|
return -EBUSY;
|
|
/*
|
|
* TNG has IRQ0 assigned to eMMC controller. But there
|
|
* are also other devices with bogus PCI configuration
|
|
* that have IRQ0 assigned. This check ensures that
|
|
* eMMC gets it. The rest of devices still could be
|
|
* enabled without interrupt line being allocated.
|
|
*/
|
|
if (dev->device != PCI_DEVICE_ID_INTEL_MRFLD_MMC)
|
|
return 0;
|
|
}
|
|
break;
|
|
default:
|
|
polarity_low = true;
|
|
break;
|
|
}
|
|
|
|
ioapic_set_alloc_attr(&info, dev_to_node(&dev->dev), 1, polarity_low);
|
|
|
|
/*
|
|
* MRST only have IOAPIC, the PCI irq lines are 1:1 mapped to
|
|
* IOAPIC RTE entries, so we just enable RTE for the device.
|
|
*/
|
|
ret = mp_map_gsi_to_irq(gsi, IOAPIC_MAP_ALLOC, &info);
|
|
if (ret < 0)
|
|
return ret;
|
|
|
|
dev->irq = ret;
|
|
dev->irq_managed = 1;
|
|
|
|
return 0;
|
|
}
|
|
|
|
static void intel_mid_pci_irq_disable(struct pci_dev *dev)
|
|
{
|
|
if (!mp_should_keep_irq(&dev->dev) && dev->irq_managed &&
|
|
dev->irq > 0) {
|
|
mp_unmap_irq(dev->irq);
|
|
dev->irq_managed = 0;
|
|
}
|
|
}
|
|
|
|
static const struct pci_ops intel_mid_pci_ops __initconst = {
|
|
.read = pci_read,
|
|
.write = pci_write,
|
|
};
|
|
|
|
/**
|
|
* intel_mid_pci_init - installs intel_mid_pci_ops
|
|
*
|
|
* Moorestown has an interesting PCI implementation (see above).
|
|
* Called when the early platform detection installs it.
|
|
*/
|
|
int __init intel_mid_pci_init(void)
|
|
{
|
|
pr_info("Intel MID platform detected, using MID PCI ops\n");
|
|
pci_mmcfg_late_init();
|
|
pcibios_enable_irq = intel_mid_pci_irq_enable;
|
|
pcibios_disable_irq = intel_mid_pci_irq_disable;
|
|
pci_root_ops = intel_mid_pci_ops;
|
|
pci_soc_mode = 1;
|
|
/* Continue with standard init */
|
|
acpi_noirq_set();
|
|
return 1;
|
|
}
|
|
|
|
/*
|
|
* Langwell devices are not true PCI devices; they are not subject to 10 ms
|
|
* d3 to d0 delay required by PCI spec.
|
|
*/
|
|
static void pci_d3delay_fixup(struct pci_dev *dev)
|
|
{
|
|
/*
|
|
* PCI fixups are effectively decided compile time. If we have a dual
|
|
* SoC/non-SoC kernel we don't want to mangle d3 on non-SoC devices.
|
|
*/
|
|
if (!pci_soc_mode)
|
|
return;
|
|
/*
|
|
* True PCI devices in Lincroft should allow type 1 access, the rest
|
|
* are Langwell fake PCI devices.
|
|
*/
|
|
if (type1_access_ok(dev->bus->number, dev->devfn, PCI_DEVICE_ID))
|
|
return;
|
|
dev->d3hot_delay = 0;
|
|
}
|
|
DECLARE_PCI_FIXUP_FINAL(PCI_VENDOR_ID_INTEL, PCI_ANY_ID, pci_d3delay_fixup);
|
|
|
|
static void mid_power_off_one_device(struct pci_dev *dev)
|
|
{
|
|
u16 pmcsr;
|
|
|
|
/*
|
|
* Update current state first, otherwise PCI core enforces PCI_D0 in
|
|
* pci_set_power_state() for devices which status was PCI_UNKNOWN.
|
|
*/
|
|
pci_read_config_word(dev, dev->pm_cap + PCI_PM_CTRL, &pmcsr);
|
|
dev->current_state = (pci_power_t __force)(pmcsr & PCI_PM_CTRL_STATE_MASK);
|
|
|
|
pci_set_power_state(dev, PCI_D3hot);
|
|
}
|
|
|
|
static void mid_power_off_devices(struct pci_dev *dev)
|
|
{
|
|
int id;
|
|
|
|
if (!pci_soc_mode)
|
|
return;
|
|
|
|
id = intel_mid_pwr_get_lss_id(dev);
|
|
if (id < 0)
|
|
return;
|
|
|
|
/*
|
|
* This sets only PMCSR bits. The actual power off will happen in
|
|
* arch/x86/platform/intel-mid/pwr.c.
|
|
*/
|
|
mid_power_off_one_device(dev);
|
|
}
|
|
|
|
DECLARE_PCI_FIXUP_FINAL(PCI_VENDOR_ID_INTEL, PCI_ANY_ID, mid_power_off_devices);
|
|
|
|
/*
|
|
* Langwell devices reside at fixed offsets, don't try to move them.
|
|
*/
|
|
static void pci_fixed_bar_fixup(struct pci_dev *dev)
|
|
{
|
|
unsigned long offset;
|
|
u32 size;
|
|
int i;
|
|
|
|
if (!pci_soc_mode)
|
|
return;
|
|
|
|
/* Must have extended configuration space */
|
|
if (dev->cfg_size < PCIE_CAP_OFFSET + 4)
|
|
return;
|
|
|
|
/* Fixup the BAR sizes for fixed BAR devices and make them unmoveable */
|
|
offset = fixed_bar_cap(dev->bus, dev->devfn);
|
|
if (!offset || PCI_DEVFN(2, 0) == dev->devfn ||
|
|
PCI_DEVFN(2, 2) == dev->devfn)
|
|
return;
|
|
|
|
for (i = 0; i < PCI_STD_NUM_BARS; i++) {
|
|
pci_read_config_dword(dev, offset + 8 + (i * 4), &size);
|
|
dev->resource[i].end = dev->resource[i].start + size - 1;
|
|
dev->resource[i].flags |= IORESOURCE_PCI_FIXED;
|
|
}
|
|
}
|
|
DECLARE_PCI_FIXUP_HEADER(PCI_VENDOR_ID_INTEL, PCI_ANY_ID, pci_fixed_bar_fixup);
|