Scott Teel 3d38f00c41 scsi: hpsa: separate monitor events from rescan worker
create new worker thread to monitor controller events
 - both the rescan and event monitor workers can cause a rescan to occur
   however for multipath we have found that we need to respond faster
   than the normal scheduled rescan interval for path fail-overs.
 - getting controller events only involves reading a register, but the
   rescan worker can obtain an updated LUN list when there is a PTRAID
   device present.
 - move common code to a separate function.
advantages:
 - detect controller events more frequently.
 - leave rescan thread interval at 30 seconds.

Reviewed-by: Scott Benesh <scott.benesh@microsemi.com>
Reviewed-by: Scott Teel <scott.teel@microsemi.com>
Reviewed-by: Kevin Barnett <kevin.barnett@microsemi.com>
Signed-off-by: Don Brace <don.brace@microsemi.com>
Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
2017-06-12 20:48:01 -04:00
..
2017-05-08 22:09:21 -04:00
2017-05-04 12:19:44 -07:00
2017-05-04 12:19:44 -07:00
2017-06-11 11:21:08 -07:00
2017-05-04 19:15:35 -07:00
2017-05-04 12:19:44 -07:00
2015-04-17 10:13:56 -07:00
2015-11-25 22:08:55 -05:00
2014-07-17 22:07:37 +02:00
2016-05-10 22:01:07 -04:00
2015-11-09 17:11:57 -08:00
2014-11-24 16:13:16 +01:00
2015-11-09 16:32:14 -08:00
2016-02-25 21:10:53 -05:00
2017-05-04 12:19:44 -07:00
2017-03-23 12:04:05 -04:00
2016-01-27 20:36:10 +08:00
2016-01-27 20:36:10 +08:00
2017-05-04 12:19:44 -07:00
2017-05-04 12:19:44 -07:00
2017-04-26 15:09:04 -06:00
2014-07-17 22:07:35 +02:00
2016-02-23 21:27:02 -05:00
2016-11-28 15:51:31 -05:00
2017-05-04 12:19:44 -07:00
2017-04-13 13:58:20 -04:00
2017-05-04 12:19:44 -07:00
2017-05-04 12:19:44 -07:00
2017-05-04 12:19:44 -07:00
2017-05-04 12:19:44 -07:00
2017-05-11 23:14:36 -04:00
2016-02-23 21:27:02 -05:00
2014-07-17 22:07:39 +02:00
2017-04-07 17:07:14 -04:00
2014-11-12 11:15:57 +01:00
2015-11-18 11:59:09 -05:00
2017-04-26 18:32:29 -04:00
2017-05-04 12:19:44 -07:00
2017-02-21 11:51:42 -08:00
2017-03-15 19:27:46 -04:00