mirror of
https://git.kernel.org/pub/scm/linux/kernel/git/torvalds/linux.git
synced 2025-01-09 06:43:09 +00:00
ad3d9c779b
The bq25892 model relies on external charger-type detection and once that is done the bq25890_charger code will update the input current and if pumpexpress is used also the input voltage. In this case, when the initial power_supply_changed() call is made from the interrupt handler, the input settings are 5V/0.5A which on many devices is not enough power to charge (while the device is on). On many devices the fuel-gauge relies in its external_power_changed callback to timely signal userspace about charging <-> discharging status changes. Add a power_supply_changed() call after updating the input current or voltage. This allows the fuel-gauge driver to timely recheck if the battery is charging after the new input settings have been applied and then it can immediately notify userspace about this. Fixes: |
||
---|---|---|
.. | ||
reset | ||
supply | ||
Kconfig | ||
Makefile |