docs(readme): clarify the color of the lights during PCB verification
This commit is contained in:
parent
243a2881ac
commit
0eecba547e
24
README.md
24
README.md
@ -40,18 +40,24 @@ If you choose the Type-C version, You can refer to the following procedure to ve
|
|||||||
2. Ensure that there are **no false shorts** between the IP2368 and Type-C pins and to GND.
|
2. Ensure that there are **no false shorts** between the IP2368 and Type-C pins and to GND.
|
||||||
3. Ensure LEDs are oriented and colored correctly.
|
3. Ensure LEDs are oriented and colored correctly.
|
||||||
4. When connected to a standard Type-C PD power supply and **without** battery.
|
4. When connected to a standard Type-C PD power supply and **without** battery.
|
||||||
1. Ensure the power supply should be around **20V**.
|
1. Ensure the red light are **on** and the blue light is **off**.
|
||||||
2. Ensure the power supply should be around **0.6W**.
|
2. Ensure the green light are on if the power supply supports 20V.
|
||||||
3. Ensure the C2 voltage should be around **12.6V**.
|
3. Ensure the power supply should be around **20V** (or 5V, 9V, 12V, 15V depending on the power supply).
|
||||||
|
4. Ensure the power supply should be around **0.6W**.
|
||||||
|
5. Ensure the C2 voltage should be around **12.6V**.
|
||||||
5. Insert a battery of less than **50%** capacity, ensure the red light blinks **4** times and then goes out.
|
5. Insert a battery of less than **50%** capacity, ensure the red light blinks **4** times and then goes out.
|
||||||
6. When connected to a standard Type-C PD power supply with a **50%** capacity battery (**Pay attention to high temperature**).
|
6. When connected to a standard Type-C PD power supply with a **50%** capacity battery (**Pay attention to high temperature**).
|
||||||
1. Ensure the red light comes on quickly and without blinking.
|
1. Ensure the red light **comes on quickly without blinking** and the blue light is **off**.
|
||||||
2. Within IC protocol negotiation, ensure the power supply should be around **0.6W**.
|
2. Ensure the green light are on if the power supply supports 20V.
|
||||||
3. After IC protocol negotiation, ensure the power supply should be about **24W** (12W for 5V, 9V, 12V, 15V).
|
3. Within IC protocol negotiation, ensure the power supply should be around **0.6W**.
|
||||||
4. After IC protocol negotiation, ensure the voltage across R9 should be **10mV** (**right** end is positive).
|
4. After IC protocol negotiation, ensure the power supply should be about **24W** (or 12W for 5V, 9V, 12V, 15V).
|
||||||
7. After unplugging the standard Type-C PD power supply, ensure the red light goes off in about 1 second.
|
5. After IC protocol negotiation, ensure the voltage across R9 should be **10mV** (**right** end is positive).
|
||||||
|
7. After unplugging the standard Type-C PD power supply, ensure the red and green lights goes off in about 1 second.
|
||||||
8. When the battery is fully charged, ensure the red light will be off and the blue light wull be on.
|
8. When the battery is fully charged, ensure the red light will be off and the blue light wull be on.
|
||||||
9. Ensure Type-C can support PD3.0 30W, APPEL 2.4A, BC1.2DCP, QC3.0 5V-12V, AFC 25W, FCP 24W, SCP 25W, etc.
|
9. When connected to a fast charging protocol tester.
|
||||||
|
1. Ensure the red light **comes on quickly without blinking** and the blue light is **off**.
|
||||||
|
2. Ensure the green light are on if you are testing outputs above 15V.
|
||||||
|
3. Ensure support PD3.0 30W, APPEL 2.4A, BC1.2DCP, QC3.0 5V-12V, AFC 25W, FCP 24W, SCP 25W, etc.
|
||||||
10. Connect the fan and make sure the fan can rotate and adjust the speed properly.
|
10. Connect the fan and make sure the fan can rotate and adjust the speed properly.
|
||||||
11. Ensure the battery level meter can correctly display the battery level.
|
11. Ensure the battery level meter can correctly display the battery level.
|
||||||
|
|
||||||
|